The GFECT-1PD2 series current sensor is a single-phase structure, cast with epoxy resin, fully enclosed insulation, safe and reliable. It is fully enclosed and insulated, safe and reliable, suitable for traditional switchgear and GIS switchgear. It is suitable for current measurement (metering) and protection in AC 50/60Hz lines with the highest voltage of 40.5kV and below.
In order to ensure good anti-interference ability, the secondary signal output terminal and signal line of the GFECT-1PD2 series current sensor have been specially shielded. Customized interface solutions can be provided according to the specific requirements of customers.
All of our GFUVE electronic current transformers are strictly comply IEC60044-8, IEC 61869-6, ANSI/IEEE C57.13, GB/T 20840.6, GB/T 20840.8, IEC/EN61010-2-032, IEC/EN 61010-2-031.
Current sensors are based on the principle of low-power coils; Integrated design, capable of simultaneously measuring three-phase current and zero sequence current and sampling protection signals; The secondary output is a safe low voltage signal, greatly reducing power consumption and generating less heat; No risk of secondary open circuit and high voltage, increased safety; Product standardization, simplified selection and ordering process, and fast delivery; Small in size and light in weight, easy to install; Meet the requirements for primary and secondary integration of the power grid; Combined with multifunctional intelligent feeder terminals (FTUs), these excellent features will bring great improvements to power protection and monitoring; High precision 0.5s; Protection class 5P10; Measurement range 0-1000A AC; Rated voltages up to 40.5kV; Holding wire diameter: φ120mm; Size: φ120x200x200x70; As a measurement and protection current transformer; Using life more than 20 years; Easily installation, with mounting bracket; Support dual ratio 1000A/1V, 20A/0.2V; IEC60044-8, IEC/EN 61869-6, GB/T 20840.6,8, ANSI/IEEE C57.13;
MV switchgears; Ring network cabinet; Air switch cabinet; Distribution monitor system; Distribution boxes; Power quality meter; Medium voltage metering system; Outdoor pole mounted circuit breaker; C-GIS switchgear; Insulating bushing;
P1, P2 is primary polarity terminal, S1, S2 is secondary polarity terminal.
P2, S2 is homonymous terminals (subtractive polarity).
Electrical parameters | |
---|---|
Standards | IEC60044-8; IEC 61869-6; NTC 2205; ANSI/IEEE C57.13; GB/T 20840.6, 8, IEC/EN61010-2-032, IEC/EN 61010-2-031 |
Accuracy class | 0.2S, 0.2, 0.5S, 0.5, 1 (IEC61869-6 standard) 5P20, 5P10, 10P10, 10P5 |
Rated primary current | 20-1000A |
Rated load impedance | ≥20kΩ |
Rated frequency | 50Hz or 60Hz |
Rated secondary current | 1V, 0.2V |
Ratio | 600A/1V(Phase current); 20A/0.2V(Zero-sequence current) |
Rated short-time thermal current | 20xIn |
Rated continuous thermal current | 120%I1n |
Secondary winding power-frequency voltage | 3kV, 1min |
Instrument security factor | FS ≤10 |
Insulation class | E |
Output signal cable | RVSP shield line L = 2.5m (length can be customized) |
Material | Polyurethane+silicon steel sheets+enameled wire+ABS |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | φ120x200x200x70 |
Jaw cable diameter(mm) | 120 |
Weight (kg) | 7 |
Operating conditions | |
Operating temperature | -40°C to +70°C |
Daily average temp | <+40°C |
Storage temperature | -40°C to +70°C |
Environment | Indoors |
Altitude | <3500 meters |
Conditions | No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current. |
Be sure to the type, current ratio, accuracy class, rated load and use of the products when you plan to make a order. Special specifications could be customized. All kinds of different specifications and parameters current transformers can be made according to your needs.